Theater Calculators
Power Conditioner Sizing (VA/Watts) Calculator
https://www.theatersizing.com/calculators/power-conditioner-sizing/
Estimate only — not a calibrated SPL meter, an acoustic report or an electrical design. Confirm with measurement.
Power Conditioner Sizing (VA/Watts) Calculator
Add the nameplate watts (or honest measurements) and keep 25% free so a laser projector lamp-up does not sag the AVR.
Inputs
Results
Please tick the box above to display the Result.
Calculation method
VA ≈ 1.25 × Σ watts. Headroom watts = 0.25 × Σ.
Exact formula
VA = 1.25 ΣP. Limits: assumes ~unity power factor, no inrush, no 240 V split from 120 V math.
Related calculations
- Will the breaker accept that sum? — will the breaker accept that sum
- Watts in become heat out — watts in become heat out
Frequently asked questions
Watts or VA?
VA = watts ÷ power factor. Gear with active PFC sits near 1, but linear-supply AVRs and amps can sit near 0.6–0.7, so their VA runs well above their watts. The 1.25 factor only covers a power factor of 0.8; when the nameplate prints volts × amps, use that.
Include the sub?
Yes. Count its draw at volume, not standby: a 300 W plate amp can pull far more than 30 W on big effects.
Laser projector idle?
Use the bright-lamp number, not eco idle.
More in this topic
All tools in this topicAmplification & power
Amplifier Power Match (SPL) Calculator
From speaker sensitivity, distance and target SPL, get required watts and whether a receiver can supply them with headroom.
Amplification & power
AV Receiver Heat Dissipation Calculator
Estimate heat in watts and BTU/h from idle draw, load and efficiency, then a starting ventilation gap.
Amplification & power
Ohm’s Law AV Rack Load Calculator
Convert rack watts and wall voltage into amps and check the 80% continuous-load breaker rule.
Amplification & power
Speaker Wire Gauge (AWG) Distance Calculator
Pick a minimum AWG so round-trip copper stays under 5% of the speaker impedance on your cable run.